PVC tongue and groove ZCF(G)-500/9 250х120х9 application
- coastal constructions, including sea constructions - PVC tongue and groove is resistant to sea salt; aquaculture pond, marinas, river ports. Wall construction provides the possibility to form a shoreline (arc, bay, etc.)
- terraced walls (using PVC tongue and groove is a quicker and cheaper way of creating terraces compared to the traditional method, as concrete wall does not need any foundation or heavy reinforcement. What is more, a hermetic wall makes more stable connection with the ground due to profile length).
- protection of foundation from groundwater (and from the forced movement of geologically unstable ground),
- woodland conservation of foundation/concrete walls from aggressive factors (great solution for landfills, animal waste separation in в in the agricultural sector, etc)
- road protection
Standard color: gray, on request - any other according to international RAL chart.
Material |
PVC |
Width |
250 mm |
Height |
120 mm |
Wall thickness |
9 mm |
Section surface area |
4826 mm2 |
Quantity of tongue and groove for 1 running meter |
4 pieces |
Weight of 1 running meter of a single sheet pile |
~7.3 kg |
Weight of 1 running meter of wall |
29.2 kg |
Weight of 1 running meter of a угловой рейки |
1.3 kg |
Length |
made to order |
Tongue and groove resistance parameters
Сalculated bending resistance of a G-300 tongue and groove wall (1m wide) is 8.5 kNm, G-300 wall stiffness (EJd) is 57.9 kNm². For temporary constructions with a project use period of not more than 5 years, the above values can be increased by 20% and 50%, respectively.
Parameters |
Unit of measurement |
Required value |
Testing method |
|
1 |
Density |
g/cm³ |
1,50 ± 0,15 |
PN-92/C-89035 |
2 |
Tension resistance |
Mpa |
>= 40 |
PN-EN ISO 527-1:1998 |
3 |
Tension elasticity |
Mpa |
>= 2600 |
PN-EN ISO 527-1:1998 |
4 |
Vicat softening point |
Co |
>= 75 |
PN-93/C-89024 Testing method ITBLL-14 |
5 |
Charpy impact test |
kJ/m² |
>= 20 |
PN-EN ISO 179-2:2001 |
6 |
Resistance to aging |
% |
<= 30 |
PN-EN ISO 513:2002 |
PVC tongue and groove endurance parameters
For the project, when checking the load-bearing capacity of sheet piles and their deformation, the following should be taken into account:
Tongue and groove section strength parameters according to the following table.
Single sheet pile |
Tongue and groove wall with a 1 m width |
||||
A[cm2] |
W[cm3] |
J [cm4] |
A[cm2] |
W[cm3] |
J [cm4] |
47,60 |
126,40 |
1072,10 |
190,40 |
505,60 |
4288,40 |
Parameters description:
A - section area
W - section modulus
J - second area moment
TONGUE AND GROOVE CATALOGUE DOWNLOAD PDF